Our 3-Phase units are designed to meet UL insulation system and UL 1561 Standard Construction requirements and are fully customizable to meet application specific requirements. V&F has experience with both copper and aluminum conductors in both open core and coil and standard/custom enclosed configurations. V&F’s powerful engineering team has the expertise and experience to address even the most complex application requirements whether it be harmonic mitigation or meeting specific electrical tolerances. V&F’s computer aided design systems will not only allow V&F to develop an optimal design from a construction and cost standpoint but also allows our engineering team the ability to “virtually prototype” 3-Phase magnetics to predict performance in a customer’s application.

Special Features

  • Multiple Domestic Production Facilities equipped to handle low volume high mix, as well as high volume large kVA Transformer Requirements.
  • Various core structures/geometries and experience with grain oriented (M3 through M6) and non-oriented steel materials
  • Customized Mounting and Bracing Options including experience with shipboard and seismic applications
  • Customizable primary and secondary voltage combinations and configurations (Delta, Wye, Auto, Zig-Zag, Scott-T)
  • Full Service Electrical and Mechanical Design of 3-Phase Transformers with Fully Customizable Electrical Specifications
  • Experience with copper and aluminum conductors in both wire and foil (strip configurations)

Capabilities

Capacity: Low VA up to 5 MVA+
Frequencies: 50 thru 400 Hz
Conductor: Copper and Aluminum (wire and foil)
Agency Approvals: UL, CUL, and CE
Insulation Classes: H (180°C) thru R (220°C)
Termination: Flying Leads, Wiring Harnesses, Screw Terminals, Bus Bar, and Loop Tap
  • 6,12, 18, and 24 Pulse Transformers

  • Medium Voltage Transformers (15 kV Class)

  • Drive Isolation

    Drive Isolation Transformers

  • Auto Transformers

    Isolation and Auto-Transformers

V&F Transformer UL File #: E311117

15-500 kVA (UL Listed Component)
Above 500 kVA Available (UL Recognized Insulation System Only)
Copper and Aluminum Conductor as well as Open Core Coil / Enclosed Configurations
Fully Customizable to meet application specific in-rush, K-Factor, impedance and reactance requirements
V&F offers full validation/verification testing in compliance with the 2016 DOE Efficiency Standard Requirements
Fully Customizable to meet application specific in-rush, K-Factor, impedance and reactance requirements

Our 3-Phase units are designed to meet UL insulation system and UL 1561 Standard Construction requirements and are fully customizable to meet application specific requirements. V&F has experience with both copper and aluminum conductors in both open core and coil and standard/custom enclosed configurations. V&F’s powerful engineering team has the expertise and experience to address even the most complex application requirements whether it be harmonic mitigation or meeting specific electrical tolerances. V&F’s computer aided design systems will not only allow V&F to develop an optimal design from a construction and cost standpoint but also allows our engineering team the ability to “virtually prototype” 3-Phase magnetics to predict performance in a customer’s application.

Special Features

  • Multiple Domestic Production Facilities equipped to handle low volume high mix, as well as high volume large kVA Transformer Requirements.
  • Various core structures/geometries and experience with grain oriented (M3 through M6) and non-oriented steel materials
  • Customized Mounting and Bracing Options including experience with shipboard and seismic applications
  • Customizable primary and secondary voltage combinations and configurations (Delta, Wye, Auto, Zig-Zag, Scott-T)
  • Full Service Electrical and Mechanical Design of 3-Phase Transformers with Fully Customizable Electrical Specifications
  • Experience with copper and aluminum conductors in both wire and foil (strip configurations)

Capabilities

Capacity: Low VA up to 5 MVA+
Frequencies: 50 thru 400 Hz
Conductor: Copper and Aluminum (wire and foil)
Agency Approvals: UL, CUL, and CE
Insulation Classes: H (180°C) thru R (220°C)
Termination: Flying Leads, Wiring Harnesses, Screw Terminals, Bus Bar, and Loop Tap
  • 6,12, 18, and 24 Pulse Transformers

  • Medium Voltage Transformers (15 kV Class)

  • Drive Isolation

    Drive Isolation Transformers

  • Auto Transformers

    Isolation and Auto-Transformers

V&F Transformer UL File #: E311117

15-500 kVA (UL Listed Component)
Above 500 kVA Available (UL Recognized Insulation System Only)
Copper and Aluminum Conductor as well as Open Core Coil / Enclosed Configurations
Fully Customizable to meet application specific in-rush, K-Factor, impedance and reactance requirements
V&F offers full validation/verification testing in compliance with the 2016 DOE Efficiency Standard Requirements
Fully Customizable to meet application specific in-rush, K-Factor, impedance and reactance requirements

Product Description

Contrary to popular belief, Lorem

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

Contrary to popular belief, Lorem

It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. It was popularised in the 1960s with the release of Letraset sheets containing Lorem Ipsum passages, and more recently with desktop publishing software like Aldus PageMaker including versions of Lorem Ipsum.

Reviews

There are no reviews yet.

Be the first to review “3-Phase Power Transformers”

Your email address will not be published. Required fields are marked *